dc.identifier.citationMalo-Urriés, Miguel; Rodríguez-Sanz, Jacobo; Borrella-Andrés, Sergio [et al.]. Influence of Time, Intensity, and Total Dose Parameters on the Ultrasound Effects of Percutaneous Electrolysis: An In Vitro Experimental Study. Healthcare, 2026, 14(4), 516. Disponible en <https://www.mdpi.com/2227-9032/14/4/516>. Fecha de acceso: 23 feb. 2026. DOI: 10.3390/healthcare14040516ca
dc.identifier.issn2227-9032ca
dc.identifier.urihttps://hdl.handle.net/20.500.12328/5215
dc.description.abstractObjective: This study aimed to quantitatively analyze the influence of time, intensity, and total dose parameters on the electrolytic effect induced by percutaneous electrolysis on cadaveric patellar tendons and to determine the relationship between these parameters and the ultrasound-based quantitative response using the UZ_eDose tool. Methods: An in vitro experimental study was conducted on cadaveric patellar tendons. A total of 45 unique combinations of percutaneous electrolysis were applied, corresponding to 15 different application times (0 to 1200 s) and three intensities of galvanic current (0.1 mA, 1 mA, and 3 mA). The electrolytic effect was quantified immediately after each application using UZ_eDose. Additionally, ultrasound visibility was recorded as a binary variable (visible or non-visible). Descriptive graphical analysis, Spearman and point-biserial correlation tests, and multiple linear regression models were conducted to explore relationships between parameters and outcomes. Results: The intensity of current showed the strongest positive correlation with the UZ_eDose values (ρ = 0.606, p < 0.001), particularly when considering only cases with maintained ultrasound visibility. The total dose was also positively correlated with UZ_eDose (ρ = 0.486, p = 0.001), whereas time alone showed no significant correlation. Loss of ultrasound visibility was significantly associated with longer application times, higher intensities, and greater total doses (p < 0.001). Multiple linear regression models confirmed the predominant role of intensity in predicting the electrolytic effect, explaining up to 62.7% of the variance when excluding non-visible cases. Conclusions: The electrolytic effect, as quantified by UZ_eDose, is primarily influenced by the intensity of the current and the cumulative dose applied. However, excessive intensities and durations can lead to gas saturation, compromising ultrasound visibility. These findings suggest that both intensity and time should be carefully balanced to maximize the therapeutic effect while preserving imaging control, supporting the use of ultrasound-based quantification tools for optimized, individualized dosimetry.
dc.format.extent14ca
dc.language.isoengca
dc.publisherMDPIca
dc.relation.ispartofHealthcareca
dc.relation.ispartofseries14;4
dc.rights© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.ca
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.otherPercutaneous electrolysisca
dc.subject.otherDosingca
dc.subject.otherQuantitative ultrasoundca
dc.subject.otherGalvanic currentca
dc.subject.otherTendinopathyca
dc.subject.otherElectrólisis percutáneaca
dc.subject.otherDosificaciónca
dc.subject.otherEcografía cuantitativaca
dc.subject.otherCorriente galvánicaca
dc.subject.otherTendinopatíaca
dc.subject.otherElectrolisi percutàniaca
dc.subject.otherDosificacióca
dc.subject.otherEcografia quantitativaca
dc.subject.otherCorrent galvànicca
dc.subject.otherTendinopatiaca
dc.titleInfluence of Time, Intensity, and Total Dose Parameters on the Ultrasound Effects of Percutaneous Electrolysis: An In Vitro Experimental Studyca
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc616.7ca
dc.identifier.doihttps://dx.doi.org/10.3390/healthcare14040516ca


Fitxers en aquest element

 

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

© 2026 by the authors.
Licensee MDPI, Basel, Switzerland.
This article is an open access article
distributed under the terms and
conditions of the Creative Commons
Attribution (CC BY) license.
Excepte que s'indiqui una altra cosa, la llicència de l'ítem es descriu com https://creativecommons.org/licenses/by/4.0/
Comparteix a TwitterComparteix a LinkedinComparteix a FacebookComparteix a TelegramComparteix a WhatsappImprimeix