Show simple item record

dc.contributor.authorReñones, Josefina
dc.contributor.authorAnton, Alfonso
dc.contributor.authorGonzález Martín, Jesús María
dc.contributor.authorCarreras, Humberto
dc.contributor.authorloro, juan
dc.date.accessioned2023-03-22T15:00:05Z
dc.date.available2023-03-22T15:00:05Z
dc.date.issued2023
dc.identifier.citationReñones, Josefina; Anton, Alfonso; González Martín, Jesús María [et al.]. Effect of conventional cataract surgery and femtosecond laser-assisted cataract surgery on bruch’s membrane opening-minimum rim width, retinal nerve fiber layer, and macular thickness. Journal of Ophthalmology, 2023, 2023, 8345333. Disponible en: <https://www.hindawi.com/journals/joph/2023/8345333/>. Fecha de acceso: 22 mar. 2023. DOI: 10.1155/2023/8345333.ca
dc.identifier.issn2090-004Xca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/3634
dc.description.abstractPurpose. To evaluate the effect of conventional cataract surgery (CCS) and femtosecond laser-assisted cataract surgery (FLACS) on Bruch’s membrane opening-minimum rim width (BMO-MRW), peripapillary retinal nerve fiber layer thickness (RNFL), and macular thickness (MT) using spectral-domain optical coherence tomography (SD-OCT). Methods. BMO-MRW, RNFL, and MT were measured using SD-OCT preoperatively, 1 month and 6 months after surgery in both CCS and FLACS groups. Differences between preoperative and postoperative values were evaluated in both groups. The postoperative changes were evaluated in each group and compared between groups. Results. A total of 146 eyes of 146 patients were included in this study, 65 underwent CCS, and 81 underwent FLACS. One month after surgery, there was an increase (in microns) of 20.93 in BMO-MRW, 4.26 in RNFL, and 7.85 in MT in CCS group (), and 17.7, 3.73, and 5.65, respectively, in FLACS group (). Six months after surgery, there was an increase of 12.53 in BMO-MRW, 1.42 in RNFL, and 4.72 in MT in CCS group (), and 13.7, 1.88, and 4.14, respectively, in FLACS group (). The postoperative changes in CCS group were similar to those in FLACS group. Conclusion. CCS as well as FLACS result in a slight increase in BMO-MRW, RNFL, and MT values one month and six months after surgery. Neither CCS nor FLACS lead to a deterioration in the parameters that define the structure of the optic nerve head and the macula. These results suggest that FLACS is as safe as CCS regarding the optic nerve head and the macula in normal eyes.en
dc.format.extent8ca
dc.language.isoengca
dc.publisherHindawica
dc.relation.ispartofJournal of Ophthalmologyca
dc.relation.ispartofseries2023
dc.relation.urihttps://www.hindawi.com/journals/joph/2023/8345333/ca
dc.rights© 2023 Josefina Reñones et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.en
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.otherCirurgia de cataractes convencionalca
dc.subject.otherCirurgia de cataractes assistida per làser de femtosegonsca
dc.subject.otherOftalmologiaca
dc.subject.otherCirugía de cataratas convencionales
dc.subject.otherCirugía de cataratas asistida por láser de femtosegundoses
dc.subject.otherOftalmologíaes
dc.subject.otherConventional cataract surgeryen
dc.subject.otherFemtosecond laser-assisted cataract surgeryen
dc.subject.otherOphthalmologyen
dc.titleEffect of conventional cataract surgery and femtosecond laser-assisted cataract surgery on bruch’s membrane opening-minimum rim width, retinal nerve fiber layer, and macular thicknessen
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc617ca
dc.identifier.doihttps://dx.doi.org/10.1155/2023/8345333ca


Files in this item

 

This item appears in the following Collection(s)

Show simple item record

© 2023 Josefina Reñones et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Except where otherwise noted, this item's license is described as https://creativecommons.org/licenses/by/4.0/
Share on TwitterShare on LinkedinShare on FacebookShare on TelegramShare on WhatsappPrint