Mostra el registre parcial de l'element

dc.contributor.authorAnton, Alfonso
dc.contributor.authorNolivos, Karen
dc.contributor.authorPazos, Marta
dc.contributor.authorFatti, Gianluca
dc.contributor.authorAyala, Miriam Eleonora
dc.contributor.authorMartínez-Prats, Elena
dc.contributor.authorPeral, Oscar
dc.contributor.authorPoposki, Vladimir
dc.contributor.authorTsiroukis, Evangelos
dc.contributor.authorMorilla-Grasa, Antonio
dc.contributor.authorComas, Merce
dc.contributor.authorCastells, Xavier
dc.date.accessioned2022-01-27T11:51:04Z
dc.date.available2022-01-27T11:51:04Z
dc.date.issued2022
dc.identifier.citationAnton, Alfonso; Nolivos, Karen; Pazos, Marta [et al.]. Diagnostic accuracy and detection rate of glaucoma screening with optic disk photos, optical coherence tomography images, and telemedicine. Journal of Clinical Medicine, 2022, 11(1), 216. Disponible en: <https://www.mdpi.com/2077-0383/11/1/216>. Fecha de acceso: 27 ene. 2022. DOI: 10.3390/jcm11010216ca
dc.identifier.issn2077-0383ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/3104
dc.description.abstractPurpose: The aim of this study was to evaluate the diagnostic accuracy of optical coherence tomography (OCT) and retinography in the detection of glaucoma through a telemedicine program. Methods: A population-based sample of 4113 persons was randomly selected. The screening examination included a fundus photograph and OCT images. Images were evaluated on a deferred basis. All participants were then invited to a complete glaucoma examination, including gonioscopy, visual field, and dilated fundus examination. The detection rate, sensitivity, specificity, and positive and negative predictive values were calculated. Results: We screened 1006 persons. Of these, 201 (19.9%) were classified as glaucoma suspects; 20.4% were identified only by retinographs, 11.9% only by OCT images, and 46.3% by both. On ophthalmic examination at the hospital (n = 481), confirmed glaucoma was found in 58 (12.1%), probable glaucoma in 76 (15.8%), and ocular hypertension in 10 (2.1%), and no evidence of glaucoma was found in 337 (70.0%). The detection rate for confirmed or probable glaucoma was 9.2%. Sensitivity ranged from 69.4% to 86.2% and specificity from 82.1% to 97.4%, depending on the definition applied. Conclusions: The combination of OCT images and fundus photographs yielded a detection rate of 9.2% in a population-based screening program with moderate sensitivity, high specificity, and predictive values of 84–96%.en
dc.format.extent11ca
dc.language.isoengca
dc.publisherMDPIca
dc.relation.ispartofJournal of Clinical Medicineca
dc.relation.ispartofseries11;1
dc.rightsThis is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.en
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.otherGlaucomaca
dc.subject.otherTomografia de coherència òpticaca
dc.subject.otherRetinografiaca
dc.subject.otherTelemedicinaca
dc.subject.otherProjeccióca
dc.subject.otherGlaucomaes
dc.subject.otherTomografía de coherencia ópticaes
dc.subject.otherRetinografíaes
dc.subject.otherTelemedicinaes
dc.subject.otherProyecciónes
dc.subject.otherGlaucomaen
dc.subject.otherOptical coherence tomographyen
dc.subject.otherRetinographyen
dc.subject.otherTelemedicineen
dc.subject.otherScreeningen
dc.titleDiagnostic accuracy and detection rate of glaucoma screening with optic disk photos, optical coherence tomography images, and telemedicineen
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc61ca
dc.subject.udc617ca
dc.identifier.doihttps://dx.doi.org/10.3390/jcm11010216ca


Fitxers en aquest element

 

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Excepte que s'indiqui una altra cosa, la llicència de l'ítem es descriu com https://creativecommons.org/licenses/by/4.0/
Comparteix a TwitterComparteix a LinkedinComparteix a FacebookComparteix a TelegramComparteix a WhatsappImprimeix