Browsing Ciències de la Salut by Subject "Ophthalmology"
Now showing items 1-15 of 15
-
Agreement among spectral-domain optical coherence tomography, standard automated perimetry, and stereophotography in the detection of glaucoma progression
(Investigative Ophthalmology & Visual Science, 2015-02)PURPOSE. The purpose of this study was to evaluate the agreement among spectral-domain optical coherence tomography, standard automated perimetry (SAP), and optic disc stereo photography in the detection ... -
Automatic glaucoma classification using color fundus images based on convolutional neural networks and transfer learning
(Biomedical Optics Express, 2019-02-01)Glaucoma detection in color fundus images is a challenging task that requires expertise and years of practice. In this study we exploited the application of different Convolutional Neural Networks (CNN) ... -
Comparison of long-term results between osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis
(The Ocular Surface, 2018)Purpose: To compare the anatomical and the functional results between osteo-odonto-keratoprosthesis (OOKP) and keratoprosthesis using tibial bone autograft (Tibial bone KPro). Methods: We reviewed the ... -
Cost and detection rate of glaucoma screening with imaging devices in a primary care center
(Clinical Ophthalmology, 2017-02-16)Purpose: To analyze the cost and detection rate of a screening program for detecting glaucoma with imaging devices. Materials and methods: In this cross-sectional study, a glaucoma screening program ... -
Effect of conventional cataract surgery and femtosecond laser-assisted cataract surgery on bruch’s membrane opening-minimum rim width, retinal nerve fiber layer, and macular thickness
(Journal of Ophthalmology, 2023)Purpose. To evaluate the effect of conventional cataract surgery (CCS) and femtosecond laser-assisted cataract surgery (FLACS) on Bruch’s membrane opening-minimum rim width (BMO-MRW), peripapillary ... -
Evaluation of RETICs glaucoma diagnostic calculators in preperimetric glaucoma
(Translational Vision Science & Technology, 2018-11)Purpose: To evaluate two glaucoma diagnostic calculators (GDC) in a group of eyes with preperimetric glaucoma (PPG). Methods: All eyes (n = 265) included in this study had ocular hypertension with ... -
In vitro mitomycin C absorption and delivery with different sponge materials used in filtering surgery
(Clinical Ophthalmology, 2016-02-11)Purpose: The purpose of this study is to evaluate and compare mitomycin C (MMC) absorption and delivery in different materials used in filtering surgery. Methods: This is an in vitro study comparing ... -
Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients
(Investigative Ophthalmology & Visual Science, 2012-12)Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional ... -
Osteo-odonto-, tibial bone and Boston keratoprosthesis in clinically comparable cases of chemical injury and autoimmune disease
(The Ocular Surface, 2019)Purpose: To compare anatomical and functional results between three types of keratoprosthesis (KPro) in chemical injury and autoimmune disease. Methods: 70 clinically comparable cases were included as ... -
Refractive changes of a new asymmetric intracorneal ring segment with variable thickness and base width: a 2D finite-element model
(PLoS ONE, 2021)Purpose: To evaluate the local geometric effects of a unilateral intrastromal ring segment with a combined variation of ring thickness and base width in a finite element simulation, and to compare it ... -
Results of retinal detachment surgery in eyes with osteo-keratoprosthesis
(Retina, 2018)Purpose: To evaluate the anatomical and functional results of pars plana vitrectomy in eyes with osteo-keratoprosthesis, who have suffered retinal detachment. Methods: An observational, retrospective ... -
Subfoveal choroidal thickness changes in carotid cavernous fistula following spontaneous resolution
(BMC Ophthalmology, 2016)Background: We report the enhanced depth imaging optical coherence tomography (EDI-OCT) characteristics and variations in a patient with subretinal fluid secondary to a carotid cavernous fistula.Case ... -
Surgical management for refractory bleb dysesthesia
(Journal of Ophthalmology, 2020-08)Purpose. To present long-term results of modified bleb-limiting conjunctivoplasty as a successful treatment for intractable bleb dysesthesia and to review the literature on the surgical management of ... -
Validation of the spanish version of the low vision quality of life questionnaire
(Journal of Optometry, 2021-04-18)Purpose: To validate the Spanish Low Vision Qualify of Life (SLVQOL) questionnaire, a quality of life instrument specifically designed for patients with visual impairment, and evaluate its psychometric ... -
Visual outcome and complications of cataract extraction after pars plana vitrectomy
(Clinical Ophthalmology, 2018)Purpose: To evaluate the visual outcomes and complications of phacoemulsification in previously vitrectomized eyes. Patients and methods: A retrospective analysis of 87 consecutive vitrectomized eyes ...