In situ U-value measurement of building envelopes through continuous low-cost monitoring
Visualitza/Obre
Autor/a
Data de publicació
2023ISSN
2214-157X
Resum
Accurate characterization of the transmittance parameter (U-value) is decisive when assessing energy demand or energy consumption of buildings. The U-value of building envelopes is usually estimated using commercial devices. These commercial solutions present several drawbacks such as their high cost, the fact that they require contact sensors to measure the surface temperature on a limited number of points and the difficulty to meet the standards for ideal measuring conditions. To solve these issues, a Hyper Efficient Arduino Transmittance-meter (HEAT) was recently proposed by the authors for monitoring the U-value based on low-cost technology. This system is now completed with the recording of time series of data based on Internet of Things protocols and the use of non-contact temperature sensors. Studying the applicability, in this case HEAT is used for characterizing walls and ceiling of a building room. To check its performance, the obtained results were compared with those derived from standards and conventional building modelling tools. The results show that the developed system is reliable according to the U-values obtained and expected for the monitored elements, with an acceptable range of uncertainty compared to the ones presented in the literature.
Tipus de document
Article
Versió del document
Versió publicada
Llengua
Anglès
Matèries (CDU)
536 - Calor. Termodinàmica
Paraules clau
Pàgines
Desconocido
Publicat per
Elsevier
Col·lecció
43
Publicat a
Case Studies in Thermal Engineering
Citació
Mobaraki, Behnam; Castilla Pascual, Francisco Javier; Lozano Galant, Fidel [et al.]. In situ U-value measurement of building envelopes through continuous low-cost monitoring. Case Studies in Thermal Engineering, 2023, 43, 102778. Disponible en: <https://www.sciencedirect.com/science/article/pii/S2214157X23000849>. Fecha de acceso: 30 jun. 2025. DOI: 10.1016/j.csite.2023.102778
Nota
The authors are indebted to the Spanish Ministry of Economy and Competitiveness for the funding provided through the research projects BIA2017-86811-C2-1-R, directed by José Turmo, BIA2017-86811-C2-2-R, directed by José Antonio Lozano-Galant and [SBPLY/19/180501/000094 project: “5D sensory system in BIM environments for characterization and energy analysis of buildings” directed by Antonio Adán and Francisco Castilla. All these projects are funded with FEDER funds. It is also to be noted that funding for this research has been provided to Behnam Mobaraki for his Ph.D. program by the Spanish Agencia Estatal de Investigación del Ministerio de Ciencia Innovación y Universidades (grant number: 2018-COB-9092).
Aquest element apareix en la col·lecció o col·leccions següent(s)
- Ciències Bàsiques [94]
Drets
© 2023 The Authors. Published by Elsevier Ltd.
Excepte que s'indiqui una altra cosa, la llicència de l'ítem es descriu com https://creativecommons.org/licenses/by-nc-nd/4.0/

