Search
Now showing items 21-30 of 38
In-vitro development of a temporal abutment screw to protect osseointegration in immediate loaded implants
(The Korean Academy of Prosthodontics, 2015-04-23)
Purpose: In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The ...
Fatigue of narrow dental implants: influence of the hardening method
(MDPI, 2020)
The use of narrow titanium dental implants (NDI) for small ridges, reduced interdental space, or missing lateral incisors can be a viable option when compared to the conventional wider dental implants. ...
Osseoinductive elements around immediate implants for better osteointegration: a pilot study in foxhound dogs
(Wiley, 2016)
Objective: The aim of this study was to evaluate the effects on osseointegration of topical applications of melatonin vs. vitamin D over surfaces of immediate implants. Materials and methods: Mandibular ...
Silver deposition on titanium surface by electrochemical anodizing process reduces bacterial adhesion of Streptococcus sanguinis and Lactobacillus salivarius
(John Wiley & Sons, 2015)
Objectives: The aim of this study was to determine the antibacterial properties of silver-doped titanium surfaces prepared with a novel electrochemical anodizing process. Material and methods: Titanium ...
Influence of the titanium implant surface treatment on the surface roughness and chemical composition
(MDPI, 2020)
The implant surface features affect the osseointegration process. Different surface treatment methods have been applied to improve the surface topography and properties. Trace of different elements may ...
Evaluation of bone loss in antibacterial coated dental implants: an experimental study in dogs
(Elsevier, 2016-12)
The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar ...
Mechanical properties of CoCr dental-prosthesis restorations made by three manufacturing processes: influence of the microstructure and topography
(MDPI, 2020)
The aim of this study is to compare the mechanical properties of three different dental restorations’ manufacturing processes (CADCAM milling, casting and laser sintering) generated by only one laboratory ...
Influence of connection type and platform diameter on titanium dental implants fatigue: non-axial loading cyclic test analysis
(MDPI, 2020)
Two-pieces dental implants must provide stability of the implant-abutment-interface. The connection type and platform diameter could influence the biomechanical resistance and stress distribution. This ...
Resonance frequency analysis by the Osstell system, using the transducer screwed to different healings abutments
(Sociedade Portuguesa de Estomatologia e Medicina Dentária, 2017)
Objectives: compare the ISQ values obtained by the Osstell ISQ, screwing the Smarpeg directly to the implant or to the new designed healing abutments of 2, 3.5 and 5 mm of height. Methods: 60 rough ...
Advances in surfaces and osseointegration in implantology. Biomimetic surfaces
(Medicina Oral, 2015)
The present work is a revision of the processes occurring in osseointegration of titanium dental implants according to different types of surfaces -namely, polished surfaces, rough surfaces obtained ...