Search
Now showing items 61-70 of 165
Novel digital technique to analyze the accuracy and intraoperative complications of orthodontic self-tapping and self-drilling microscrews placement techniques: an in vitro study
(Elsevier, 2022)
Introduction: The objectives of this study were to analyze and compare the accuracy and intraoperative complications of orthodontic self-tapping and orthodontic self-drilling microscrew placement ...
Surface comparison of three different commercial custom-made titanium meshes produced by SLM for dental applications
(MDPI, 2020)
The use of individualized titanium meshes has been referred to in scientific literature since 2011. There are many advantages to its use, however, the main complications are related to early or late ...
Mechanical characterization of dental prostheses manufactured with PMMA–graphene composites
(Materials, 2022)
The use of a PMMA composite with graphene is being commercialized for application as dental prostheses. The different proportions of fibers provide a wide range of colors that favors dental esthetics ...
The characterization of titanium particles released from bone-level titanium dental implants: effect of the size of particles on the ion release and cytotoxicity behaviour
(Materials, 2022)
Many studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the ...
Citric acid in the passivation of titanium dental implants: corrosion resistance and bactericide behavior
(MDPI, 2022)
The passivation of titanium dental implants is performed in order to clean the surface and obtain a thin layer of protective oxide (TiO2) on the surface of the material in order to improve its behavior ...
Effect of load distribution on trunk muscle activity with lunge exercises in amateur athletes: cross-sectional study
(MDPI, 2023)
Background: The effect of load distribution applied to the trunk musculature with lunge exercises has yet to be determined. The aim of this study was to evaluate the effect of load placement using ...
Tooth transplantation and orthodontic movements
(Wolters Kluwer, 2020)
Dental autotransplants have been performed successfully for many years, but little has been written about its relationship with orthodontics. This article is a review which analyses and highlights all ...
Relevant aspects of the dental implant design on the insertion torque, resonance frequency analysis (RFA) and micromobility: an in vitro study
(MDPI, 2023)
The major problems for the osseointegration of dental implants are the loosening of the screw that fixes the dental implant to the abutment and the micromovements that are generated when mechanical loads ...
Incidence of peri-implantitis and relationship with different conditions: a retrospective study
(MDPI, 2022)
Articles on the prevalence of peri-implant diseases showed that 90% of peri-implant tissues had some form of inflammatory response and a prevalence of peri-implantitis from 28% to 51% according to various ...
In vitro comparison of the accuracy of four intraoral scanners and three conventional impression methods for two neighboring implants
(Public Library of Science, 2020)
Purpose: To determine whether the accuracy of two-implant model impressions taken with optical scanners was inferior to that of those taken with elastomeric materials. Materials and Methods: Impressions ...