TRUShape Versus XP-endo Shaper: A Micro–computed Tomographic Assessment and Comparative Study of the Shaping Ability - An In Vitro Study
Autor/a
Fecha de publicación
2020ISSN
0099-2399
Resumen
Introduction: The aim of this study was to evaluate and compare the shaping ability of XP-endo Shaper (XP; FKG Dentaire, La Chaux-de-Fonds, Switzerland) and TRUShape (TS; Dentsply/Tulsa Dental Specialties, Tulsa, OK) during the preparation of moderated curved root canals using micro–computed tomographic imaging. Methods: Twenty human maxillary premolars with 2 roots were randomly separated into 2 groups of 10 teeth, which were scanned before and after root canal preparation using the SkyScan 1275 X-ray microtomograph (Bruker micro-CT, Kontich, Belgium) at a nominal resolution of <4 μm. Premolars and irrigant were maintained at 37° before and during preparation; group 1 was treated using XP and group 2 with TS. After preparation, researchers measured the amount of dentin removed, untreated superficies of canal walls, root canal volume, degree of canal transportation, and centering ability. Values of central tendency and dispersion were calculated using Statgraphics Centurion XV software (StatPoint Technologies, Inc, Warrenton, VA); means and median were compared using the Mann-Whitney-Wilcoxon test. The level of significance was set at 5% (P < .05). Results: No significant statistical differences were observed between the 2 groups in shaping ability, untreated superficies of canal walls, degree of canal transportation, and centering ability (P > .05). Conclusions: Instrumentation of moderately curved root canals using the XP single file and the TS file system were equally effective. XP and TS maintained the original anatomy of the root canals and showed a similar percentage of untreated canal walls, centered ability, and minimal apical transportation.
Tipo de documento
Artículo
Versión del documento
Versión publicada
Lengua
Inglés
Materias (CDU)
616.3 - Patología del aparato digestivo. Odontología
Palabras clave
Páginas
5
Publicado por
Elsevier
Colección
46; 2
Publicado en
Journal of Endodontics
Citación
Perez Morales, Maria de las Nieves; González Sánchez, José Antonio; Olivieri Fernández, Juan Gonzalo [et al.]. TRUShape Versus XP-endo Shaper: A Micro–computed Tomographic Assessment and Comparative Study of the Shaping Ability—An In Vitro Study. Journal of Endodontics, 2020, 46(2), p. 271-276. Disponible en: <https://www.sciencedirect.com/science/article/pii/S0099239919308362?via%3Dihub>. Fecha de acceso: 29 ene. 2025. DOI: 10.1016/j.joen.2019.10.027
Este ítem aparece en la(s) siguiente(s) colección(ones)
- Odontologia [334]
Derechos
© 2019 American Association of Endodontists.