Show simple item record

dc.contributor.authorGargallo-Albiol, Jordi
dc.contributor.authorZilleruelo-Pozo, María José
dc.contributor.authorLucas-Taulé, Ernest
dc.contributor.authorMuñoz Peñalver, Jesús
dc.contributor.authorPaternostro-Betancourt, Daniel
dc.contributor.authorHernandez Alfaro, Federico
dc.date.accessioned2025-01-16T14:27:36Z
dc.date.available2025-01-16T14:27:36Z
dc.date.issued2022
dc.identifier.citationGargallo-Albiol, Jordi; Zilleruelo-Pozo, María José; Lucas-Taulé, Ernest [et al.]. Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study. Clinical Oral Investigations, 2022, 26, p. 2783-2791. Disponible en: <https://link.springer.com/article/10.1007/s00784-021-04254-3>. Fecha de acceso: 16 ene. 2025. DOI: 10.1007/s00784-021-04254-3ca
dc.identifier.issn1436-3771ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/4543
dc.description.abstractObjective: A cohort prospective study was conducted to assess the three-dimensional positioning accuracy of the implant between pre-surgical and the final implant position using a static fully guided approach in the posterior area of the jaws. Materials and methods: A total of 60 implants (30 patients) were digitally analyzed after superimposing the Digital Imaging and Communications in Medicine (DICOM) files obtained from the Cone Beam Computed Tomography (CBCT) pre- and post-implant placement. The software calculations included deviations at the implant shoulder and at the implant apex, global deviation (3D offset), and angle deviation. Statistical analysis was performed with α = 0.05. Results: Considering the total number of implants, mesiodistal, buccolingual, and apicocoronal mean deviations at the shoulder and implant apex were equal or below 0.21 ± 0.69 mm, and only the buccolingual mean deviation at the apex reached up to 0.67 ± 1.06 mm. The mesiodistal and apicocoronal deviations were not statistically significant at both the shoulder and apex levels of the implant. The mean total angular deviation was 5.62° ± 4.09. The main limitation of this surgical approach was the requirement for a wide mouth opening. Conclusions: Static fully guided surgery for dental implant placement exhibits minimum deviations respect to presurgical planning. The main limitation in the posterior areas is the requirement for a wide mouth opening. Clinical relevance: Even with minimum deviations clinically acceptable, precautions and safety margins must be respected when using static full-guided surgery to place dental implants.ca
dc.format.extent8ca
dc.language.isoengca
dc.publisherSpringer Natureca
dc.relation.ispartofClinical Oral Investigationsca
dc.relation.ispartofseries26
dc.rights© 2022 Springer Natureca
dc.subject.otherPrecisióca
dc.subject.otherCirurgia assistida per ordinadorca
dc.subject.otherAssistida per ordinadorca
dc.subject.otherImatge tridimensionalca
dc.subject.otherImplants dentalsca
dc.subject.otherPrecisiónca
dc.subject.otherCirugía asistida por computadoraca
dc.subject.otherCirugía asistida por computadoraca
dc.subject.otherImágenes tridimensionalesca
dc.subject.otherImplantes dentalesca
dc.subject.otherAccuracyca
dc.subject.otherComputer-aided surgeryca
dc.subject.otherComputer-assistedca
dc.subject.otherThree-dimensional imagingca
dc.subject.otherDental implantsca
dc.titleAccuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective studyca
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc616.3ca
dc.identifier.doihttps://dx.doi.org/10.1007/s00784-021-04254-3ca


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record