Mostrar el registro sencillo del ítem

dc.contributor.authorQuispe-López, Norberto
dc.contributor.authorMartín-Martín, Soraya
dc.contributor.authorGÓMEZ-POLO, CRISTINA
dc.contributor.authorFigueras-Alvarez, Oscar
dc.contributor.authorsanchez jorge, MARIA ISABEL
dc.contributor.authorMONTERO, JAVIER
dc.date.accessioned2024-07-18T08:16:48Z
dc.date.available2024-07-18T08:16:48Z
dc.date.issued2024
dc.identifier.citationQuispe-López, Norberto; Martín-Martín, Soraya; Gómez-Polo, Cristina [et al.]. Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality. Applied Sciences, 2024, 14(11), 4841. Disponible en: <https://www.mdpi.com/2076-3417/14/11/4841>. Fecha de acceso: 18 jul. 2024. DOI: 10.3390/app14114841ca
dc.identifier.issn2076-3417ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/4314
dc.description.abstractSome evidence supports the influence of implant macro-design on primary stability. Additionally, tactile perception can be used to assess implant stability when placing the implant. This research aimed to quantify the primary and secondary stability of three implant systems with two different macro geometries (cylindrical and conical) determined based on the insertion torque and the implant stability quotient (ISQ) at the moment of implant placement as a function of implant-related factors (length, width, dental arch, and implant location in the arch), intraoperative factors (bone density determined subjectively by the clinician’s tactile perception), and patient-related factors (age, gender, and bone density determined objectively based on cone beam computed tomography (CBCT). Methods: 102 implants from three implant systems with two different macro geometries (conical and cylindrical) were placed in 53 patients. The insertion torque, the ISQ at the implant placement (ISQ0), and the bone quality according to the clinician’s tactile sensation were recorded on the day of the surgery. After a three-month healing period, the ISQ was re-evaluated (ISQ3). Results: The cylindrical implants exhibited significantly higher insertion torque and ISQ values at the moment of the surgery and after three months compared to the conical implants. The cylindrical implants also showed significantly lower indices of tactile evaluation of bone quality during the implant placement surgery. However, no differences were demonstrated in the bone density measured objectively using CBCT. (4) Conclusions: The cylindrical implants achieved the highest values for primary stability (Newtons × centimeter (Ncm) and ISQ) and secondary stability (ISQ after three months). The insertion torque was the variable that most influenced the ISQ on the day of the surgery. The implant location (incisors–canines, bicuspids–molars) and the implant macro geometry were the variables that most influenced the secondary stability (ISQ at three months).ca
dc.format.extent17ca
dc.language.isoengca
dc.publisherMDPIca
dc.relation.ispartofApplied Sciencesca
dc.relation.ispartofseries14;11
dc.rights© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).ca
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.otherImplants dentalsca
dc.subject.otherDensitat òssiaca
dc.subject.otherMacrodissenyca
dc.subject.otherEstabilitat de l'implantca
dc.subject.otherTomografia computeritzadaca
dc.subject.otherQualitat òssiaca
dc.subject.otherImplantes dentalesca
dc.subject.otherDensidad oseaca
dc.subject.otherMacrodiseñoca
dc.subject.otherEstabilidad del implanteca
dc.subject.otherTomografía computarizadaca
dc.subject.otherCalidad óseaca
dc.subject.otherDental implantsca
dc.subject.otherBone densityca
dc.subject.otherMacro-designca
dc.subject.otherImplant stabilityca
dc.subject.otherComputerized tomographyca
dc.subject.otherBone qualityca
dc.titlePrimary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone qualityca
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc616.3ca
dc.identifier.doihttps://dx.doi.org/10.3390/app14114841ca


Ficheros en el ítem

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Excepto si se señala otra cosa, la licencia del ítem se describe como https://creativecommons.org/licenses/by/4.0/
Compartir en TwitterCompartir en LinkedinCompartir en FacebookCompartir en TelegramCompartir en WhatsappImprimir