Mostrar el registro sencillo del ítem
Properties of superelastic nickel–titanium wires after clinical use
dc.contributor.author | Alcaraz, Inés | |
dc.contributor.author | Moyano, Javier | |
dc.contributor.author | Pàmies, Ariadna | |
dc.contributor.author | Ruiz, Guillem | |
dc.contributor.author | Artés, Montserrat | |
dc.contributor.author | Gil Mur, Francesc Xavier | |
dc.contributor.author | Puigdollers, Andreu | |
dc.date.accessioned | 2024-02-15T11:43:23Z | |
dc.date.available | 2024-02-15T11:43:23Z | |
dc.date.issued | 2023 | |
dc.identifier.citation | Alcaraz, Inés; Moyano, Javier; Pàmies, Ariadna [et al.]. Properties of superelastic nickel–titanium wires after clinical use. Materials, 2023, 16(16), 5604. Disponible en: <https://www.mdpi.com/1996-1944/16/16/5604>. Fecha de acceso: 15 feb. 2024. DOI: 10.3390/ma16165604 | ca |
dc.identifier.issn | 1996-1944 | ca |
dc.identifier.uri | http://hdl.handle.net/20.500.12328/4103 | |
dc.description.abstract | The aim of the present study was to describe and determine changes in the superelastic properties of NiTi archwires after clinical use and sterilization. Ten archwires from five different manufacturers (GAC, 3M, ODS, GC, FOR) were cut into two segments and evaluated using a three-point bending test in accordance with ISO 14841:2006. The center of each segment was deflected to 3.1 mm and then unloaded to 0 N to obtain a load–deflection curve. Deflection at the end of the plateau and forces at 3, 2, 1 and 0.5 mm on the unloading curve were recorded. Plateau slopes were calculated at 2, 1 and 0.5 mm of deflection. Data obtained were statistically analyzed to determine differences (p < 0.001). Results showed that the degree of superelasticity and exerted forces differed significantly among brand groups. After three months of clinical use, FOR released a greater force for a longer activation period. GC, EURO and FOR archwires seemed to lose their mechanical properties. GC wires released more force than other brand wires after clinical use. Regarding superelasticity after sterilization, GAC, 3M and FOR wires recovered their properties, while EURO archwires lost more. | ca |
dc.format.extent | 12 | ca |
dc.language.iso | eng | ca |
dc.publisher | MDPI | ca |
dc.relation.ispartof | Materials | ca |
dc.relation.ispartofseries | 16;16 | |
dc.rights | © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). | ca |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject.other | NiTi | ca |
dc.subject.other | Superelasticitat | ca |
dc.subject.other | Esterilització | ca |
dc.subject.other | Propietats mecàniques | ca |
dc.subject.other | NiTi | ca |
dc.subject.other | Superelasticidad | ca |
dc.subject.other | Esterilización | ca |
dc.subject.other | Propiedades mecánicas | ca |
dc.subject.other | NiTi | ca |
dc.subject.other | Superelasticity | ca |
dc.subject.other | Sterilization | ca |
dc.subject.other | Mechanical properties | ca |
dc.title | Properties of superelastic nickel–titanium wires after clinical use | ca |
dc.type | info:eu-repo/semantics/article | ca |
dc.description.version | info:eu-repo/semantics/publishedVersion | ca |
dc.rights.accessLevel | info:eu-repo/semantics/openAccess | |
dc.embargo.terms | cap | ca |
dc.subject.udc | 616.3 | ca |
dc.identifier.doi | https://dx.doi.org/10.3390/ma16165604 | ca |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Odontologia [237]