Impact of design and length on the accuracy of closed tray transfer copings
dc.contributor.author | Roig, Elena | |
dc.contributor.author | Álvarez Maldonado, Natalia | |
dc.contributor.author | Garza, Luis Carlos | |
dc.contributor.author | Vallés, Marta | |
dc.contributor.author | Espona, José | |
dc.contributor.author | Roig, Miguel | |
dc.date.accessioned | 2023-03-15T15:34:58Z | |
dc.date.available | 2023-03-15T15:34:58Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Roig, Elena; Álvarez Maldonado, Natalia; Garza, Luis Carlos [et al.]. Impact of design and length on the accuracy of closed tray transfer copings. Journal of Clinical and Experimental Dentistry. 2019, 11(8), e707-712. Disponible en: <https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6776411/>- Fecha de acceso: 15 mar. 2023. DOI: 10.4317/jced.55588 | ca |
dc.identifier.issn | 1989-5488 | ca |
dc.identifier.uri | http://hdl.handle.net/20.500.12328/3615 | |
dc.description.abstract | Background: The aim of this study was to evaluate the accuracy of two closed-tray transfer copings for implant impressions (a new design vs. an old design) in two different lengths (short and long). Material and Methods: Four groups of transfer copings (NS - new short, NL - new long, OS - old short and OL - old long) were tested. An epoxy resin model was prepared of missing teeth 1.4, 1.5 and 1.6. Two Alpha-Bio analogues were placed in position of teeth 1.4 and 1.6, at a 10o angulation. Two calibrated operators took 10 closed-tray impressions for each group with polyether in a Rim-Lock impression tray. Results: After measuring and comparing impressions, a significant difference was found between the two new transfer copings and the old short transfer coping. Conclusions: The new transfer coping design significantly improved impression accuracy. An adequate transfer coping design for the closed-tray impression technique can help to achieve clinically acceptable impressions for two-unit implant supported bridges. | en |
dc.format.extent | 5 | ca |
dc.language.iso | eng | ca |
dc.publisher | Medicina Oral S.L. | ca |
dc.relation.ispartof | Journal of Clinical and Experimental Dentistry | ca |
dc.relation.ispartofseries | 11;8 | |
dc.relation.uri | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6776411/ | ca |
dc.rights | © 2019 Medicina Oral S.L. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. | en |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/deed.es | |
dc.subject.other | Safata tancada | ca |
dc.subject.other | Cop d'impressió | ca |
dc.subject.other | Cop de transferència | ca |
dc.subject.other | Impressió d'implant | ca |
dc.subject.other | Cubeta cerrada | es |
dc.subject.other | Cofia de impresión | es |
dc.subject.other | Cofia de transferencia | es |
dc.subject.other | Impresión de implante | es |
dc.subject.other | Closed tray | en |
dc.subject.other | Impression coping | en |
dc.subject.other | Transfer coping | en |
dc.subject.other | Implant impression | en |
dc.title | Impact of design and length on the accuracy of closed tray transfer copings | en |
dc.type | info:eu-repo/semantics/article | ca |
dc.description.version | info:eu-repo/semantics/publishedVersion | ca |
dc.rights.accessLevel | info:eu-repo/semantics/openAccess | |
dc.embargo.terms | cap | ca |
dc.subject.udc | 616.3 | ca |
dc.identifier.doi | https://dx.doi.org/10.4317/jced.55588 | ca |