Mostra el registre parcial de l'element

dc.contributor.authorBrancacci, Erika
dc.contributor.authorGarcía González, Susana
dc.contributor.authorAndrea, Galve-Huertas
dc.contributor.authorBennani, Aida
dc.contributor.authorHernandez Alfaro, Federico
dc.contributor.authorAboul-Hosn Centenero, Samir Carlos
dc.date.accessioned2023-03-15T09:58:44Z
dc.date.available2023-03-15T09:58:44Z
dc.date.issued2023
dc.identifier.citationBrancacci, Erika; García González, Susana; Andrea, Galve-Huertas [et al.]. Influence of insertion torques on the surface integrity in different dental implants: an ex vivo descriptive study. Materials, 2023, 16(6), 2330. Disponible en: <https://www.mdpi.com/1996-1944/16/6/2330>. Fecha de acceso: 15 mar. 2023. DOI: 10.3390/ma16062330ca
dc.identifier.issn1996-1944ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/3611
dc.description.abstractBackground: The primary objective of this ex vivo study was to assess the influence of increasing insertion torques on three types of dental implants and possible alterations of their microgeometry after the application of three different torque intensities. Methods: 27 implants of 3 different implant brands (Groups A, B and C) were placed in cow ribs using 30 Ncm, 45 Ncm and 55 Ncm insertion torques. The implants were subsequently removed using trephine burs, and SEM analysis was carried out in order to detect implant surface and connection changes, as compared to the implant controls. Results: Surface deformations were predominantly observed on the third apical part of the implants. The alterations presented with increasing insertion torques, with 45 Ncm being the threshold value. Prosthetic connections were also compromised. Conclusions: The changes sustained by the implants were proportional to the insertion torque they were subjected to; 45 Ncm and greater insertion torques resulted in more consistent damage, both on the implant surface and the implant connection.en
dc.format.extent13ca
dc.language.isoengca
dc.publisherMDPIca
dc.relation.ispartofMaterialsca
dc.relation.ispartofseries16;6
dc.relation.urihttps://www.mdpi.com/1996-1944/16/6/2330ca
dc.rights© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).en
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.otherSuperfície de l'implantca
dc.subject.otherConnexió d'implantsca
dc.subject.otherCanvi topogràficca
dc.subject.otherParell d'insercióca
dc.subject.otherSuperficie del implantees
dc.subject.otherConexión de implantees
dc.subject.otherCambio topográficoes
dc.subject.otherPar de inserciónes
dc.subject.otherImplant surfaceen
dc.subject.otherImplant connectionen
dc.subject.otherTopographic changeen
dc.subject.otherInsertion torqueen
dc.titleInfluence of insertion torques on the surface integrity in different dental implants: an ex vivo descriptive studyen
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc616.3ca
dc.identifier.doihttps://dx.doi.org/10.3390/ma16062330ca


Fitxers en aquest element

 

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Excepte que s'indiqui una altra cosa, la llicència de l'ítem es descriu com https://creativecommons.org/licenses/by/4.0/
Comparteix a TwitterComparteix a LinkedinComparteix a FacebookComparteix a TelegramComparteix a WhatsappImprimeix