Show simple item record

dc.contributor.authorHerrero-Climent, Mariano
dc.contributor.authorLópez-Jarana, P.
dc.contributor.authorLemos, B. F.
dc.contributor.authorGil Mur, Francisco Javier
dc.contributor.authorFalcao-Costa, Carlos
dc.contributor.authorRíos-Santos, José-Vicente
dc.contributor.authorRÍOS-CARRASCO, BLANCA
dc.date.accessioned2020-05-28T15:02:40Z
dc.date.available2020-05-28T15:02:40Z
dc.date.issued2020
dc.identifier.citationHerrero-Climent, M.; López-Jarana, P.; Lemos, B. F. [et al.]. Relevant design aspects to improve the stability of titanium dental implants. Materials, 2020, 13(8), p. 1-12. Disponible en: <https://www.mdpi.com/1996-1944/13/8/1910>. Fecha de acceso: 28 may. 2020. DOI: 10.3390/ma13081910.ca
dc.identifier.issn1996-1944ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/1553
dc.description.abstractPost-extractional implants and immediate loading protocols are becoming much more frequent in everyday clinical practice. Given the existing literature about tapered implants, the objective of this paper was to understand whether implant shape had a direct influence on the results of the insertion torque (IT) and implant stability quotient (ISQ). Seven tapered implant prototypes were developed and distributed into three groups and compared with a control cylindrical implant—VEGA by Klockner Implant System. The implants were inserted into bovine bone type III according to Lekholm and Zarb Classification. The sample size was n = 30 for the three groups. Final IT was measured with a torquemeter, and the ISQ was measured with Penguin Resonance Frequency Analysis (RFA). Modifications done to the Prototype I did not reveal higher values of the ISQ and IT when compared to VEGA. In the second group, when comparing the five prototypes (II–VI) with VEGA, it was seen that the values of the ISQ and IT were not always higher, but there were two values of the ISQ that were statistically significantly higher with the 4.0 mm diameter Prototypes II (76.3 ± 6.1) and IV (78 ± 3.7). Prototype VII was the one with higher and significant values of the ISQ and IT. In both diameters and in both variables, all differences were statistically significant enough to achieve the higher values of primary stability values (IT and ISQ). Given the limitations of this study, it can be concluded that when there is an increase of the diameter of the implant and body taper, there is an increase of the ISQ and IT, showing that the diameter of the implant is an important criteria to obtain higher values of primary stability.ca
dc.format.extent12ca
dc.language.isoengca
dc.publisherMDPIca
dc.relation.ispartofMaterialsca
dc.relation.ispartofseries13;8
dc.rights© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open accessarticle distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).ca
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.otherImplants dentalsca
dc.subject.otherOdontologia
dc.subject.otherImplantes dentales
dc.subject.otherOdontología
dc.subject.otherDental implants
dc.subject.otherOdontology
dc.titleRelevant design aspects to improve the stability of titanium dental implantsca
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/acceptedVersionca
dc.embargo.termscapca
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN/RTI2018-098075-B-C22
dc.subject.udc616.3ca
dc.identifier.doihttps://dx.doi.org/10.3390/ma13081910ca


Files in this item

 

This item appears in the following Collection(s)

Show simple item record

© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open accessarticle distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Except where otherwise noted, this item's license is described as https://creativecommons.org/licenses/by/4.0/
Share on TwitterShare on LinkedinShare on FacebookShare on TelegramShare on WhatsappPrint