Show simple item record

dc.contributor.authorBRAVO-GONZÁLEZ, LUIS-ALBERTO
dc.contributor.authorGonzález de Cabañes, A.
dc.contributor.authorManero, José María
dc.contributor.authorRupérez de Gracia, Elisa
dc.contributor.authorGil Mur, Francisco Javier
dc.date.accessioned2020-05-10T13:52:39Z
dc.date.available2020-05-10T13:52:39Z
dc.date.issued2013-10-24
dc.identifier.citationBravo-González, Luis Alberto; González de Cabañes, A.; Manero, Jose M. [et al.]. NiTi superelastic orthodontic archwires with polyamide coating. Journal of Materials Science: Materials in Medicine, 2014, 25, p. 555-560. Disponible en: <https://link.springer.com/article/10.1007%2Fs10856-013-5070-7>. Fecha de acceso: 10 may. 2020. DOI: 10.1007/s10856-013-5070-7ca
dc.identifier.issn0957-4530ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/1517
dc.description.abstractTwenty orthodontic archwires with 55.2 % Ni and 44.8 % Ti (% weight) were subjected to a dipping treatment to coat the NiTi surface by a polyamide polymer. It has been selected a Polyamide 11 due to its remarkable long lasting performance. The transformation temperatures as well as the transformation stresses of the NiTi alloy were determined in order to know whether the coating process can alter its properties. The adhesive wear tests have been demonstrated that the wear rates as well as the dynamic friction coefficients μ of polymer coated wires are much lower than metallic wires. The corrosion studies have shown that the use of this polymer, as coating, seals the NiTi surface to prevent corrosion and the release of nickel ions. The average decrease of Ni ions release due to this coating is around 85 %.ca
dc.format.extent34ca
dc.language.isoengca
dc.publisherSpringerca
dc.relation.ispartofJournal of Materials Science: Materials in Medicineca
dc.relation.ispartofseries25;
dc.rights© 2020 Springer Nature Switzerland AG.ca
dc.subject.otherOrtodònciaca
dc.subject.otherTemperatura
dc.subject.otherSaliva
dc.subject.otherAdhesius
dc.subject.otherFricció
dc.subject.otherOrtodoncia
dc.subject.otherTemperatura
dc.subject.otherSaliva
dc.subject.otherAdhesivos
dc.subject.otherFricción
dc.subject.otherOrthodontics
dc.subject.otherTemperature
dc.subject.otherSaliva
dc.subject.otherAdhesives
dc.titleNiTi superelastic orthodontic archwires with polyamide coatingca
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/acceptedVersionca
dc.embargo.termscapca
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO/6PN/MAT2012-30706ca
dc.subject.udc616.3ca
dc.identifier.doihttps://dx.doi.org/10.1007/s10856-013-5070-7ca


Files in this item

 

This item appears in the following Collection(s)

Show simple item record

Share on TwitterShare on LinkedinShare on FacebookShare on TelegramShare on WhatsappPrint