Buscar
Mostrando ítems 1-10 de 19
Corrosion resistance and ion release of dental prosthesis of CoCr obtained by CAD-CAM milling, casting and laser sintering
(MDPI, 2020)
Corrosion resistance and ion release behavior have been evaluated for thirty dental restoration samples obtained by three different manufacturing systems: computer-aided design and manufacturing (CAD-CAM), ...
Relevant design aspects to improve the stability of titanium dental implants
(MDPI, 2020)
Post-extractional implants and immediate loading protocols are becoming much more frequent in everyday clinical practice. Given the existing literature about tapered implants, the objective of this paper ...
Influence of implant design and under-preparation of the implant site on implant primary stability: an In vitro study
(MDPI, 2020)
The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two ...
Influence of bone-level dental implants placement and of cortical thickness on osseointegration: in silico and In vivo analyses
(MDPI, 2022)
The purpose of this research is to study the biomechanical response of dental implants in bone-level type locations, 0.5 mm above and below the bone level. In addition, the influence of the thickness ...
Fatigue of narrow dental implants: influence of the hardening method
(MDPI, 2020)
The use of narrow titanium dental implants (NDI) for small ridges, reduced interdental space, or missing lateral incisors can be a viable option when compared to the conventional wider dental implants. ...
Effect of the acid-etching on grit-blasted dental implants to improve osseointegration: histomorphometric analysis of the bone-implant contact in the rabbit tibia model
(MDPI, 2021)
Previous studies have shown that the most reliable way to evaluate the success of an implant is by bone-to-implant contact (BIC). Recent techniques allow modifications to the implant surface that improve ...
Accuracy of implant casts generated with conventional and digital impressions: an In vitro study
(MDPI, 2018)
Purpose: The aim of this study was to compare the accuracy of digital dental impressions with the accuracy of impressions obtained via conventional techniques. Methods: Two different master models were ...
Evaluation of titanium dental implants after early failure of osseointegration by means of X-ray photoelectron spectoscopy, electron microscopy and histological studies
(Scientific Research Publishing, 2010-11)
In this work, we analysed 56 clinically failed and retrieved implants by means of scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and histological studies. The surface ...
Effect of different implant designs on strain and stress distribution under non-axial loading: a three-dimensional finite element analysis
(MDPI, 2020)
Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and ...
Mechanical properties of CoCr dental-prosthesis restorations made by three manufacturing processes: influence of the microstructure and topography
(MDPI, 2020)
The aim of this study is to compare the mechanical properties of three different dental restorations’ manufacturing processes (CADCAM milling, casting and laser sintering) generated by only one laboratory ...