Search
Now showing items 31-39 of 39
Potencial cariogénico de las bebidas de origen vegetal en comparación a la leche de origen bovino. Revisión bibliográfica
(SEOP ; Aran Ediciones, 2020)
Introducción: el consumo de bebidas de origen vegetal como sustitutos de la leche de origen animal no sólo va en aumento en la población adulta, sino que también en la pediátrica. El efecto de este tipo ...
Effectiveness of a self-management programme in the treatment of antivitamin K oral anticoagulants. A feasibility study
(Elsevier, 2020)
Introducción y objetivo: Evaluar la eficacia de un programa de autocontrol en pacientes con tratamiento anticoagulante oral (TAO) en el mantenimiento del nivel ratio internacional normalizada (INR) en ...
Influence of connection type and platform diameter on titanium dental implants fatigue: non-axial loading cyclic test analysis
(MDPI, 2020)
Two-pieces dental implants must provide stability of the implant-abutment-interface. The connection type and platform diameter could influence the biomechanical resistance and stress distribution. This ...
Corrosion resistance and ion release of dental prosthesis of CoCr obtained by CAD-CAM milling, casting and laser sintering
(MDPI, 2020)
Corrosion resistance and ion release behavior have been evaluated for thirty dental restoration samples obtained by three different manufacturing systems: computer-aided design and manufacturing (CAD-CAM), ...
Short implants (<8mm) versus longer implants (≥8mm) with lateral sinus floor augmentation in posterior atrophic maxilla: a meta-analysis of RCT`s in humans
(Medicina Oral, 2020)
Background: One of the greatest challenges that dentists face today is to rehabilitate severe atrophied alveolar ridges in partially and completely edentulous patients with implants. Despite the high ...
Influence of the CAD-CAM systems on the marginal accuracy and mechanical properties of dental restorations
(MDPI, 2020)
The aim of this study was to compare the quality of different computer-assisted-design and computer assisted manufacturing systems (CAD-CAM) generated by only one scanner, focusing on vertical fit ...
Evaluation of endovenous sedation using BIS monitoring in dentistry. A systematic review
(Medicina Oral, 2020)
Background: The aim of the present review was evaluate the utility and validity of the Bispectral Index (BIS) in dental treatment carried out under endovenous sedation, and compare its efficacy with ...
Short implants (<8mm) versus longer implants (≥8mm) with lateral sinus floor augmentation in posterior atrophic maxilla: a meta-analysis of RCT's in humans
(Medicina Oral Patologia Oral y Cirugia Bucal, 2020)
Background: One of the greatest challenges that dentists face today is to rehabilitate severe atrophied alveolar ridges in partially and completely edentulous patients with implants. Despite the high ...
Polyethylene glycol pulsed electrodeposition for the development of antifouling coatings on titanium
(MDPI, 2020)
Titanium dental implants are widely used for the replacement of damaged teeth. However, bacterial infections at the interface between soft tissues and the implant can impair the functionality of the ...