Search
Now showing items 1-10 of 13
Enamel evaluation after debonding of fixed retention and polishing treatment with three different methods
(MDPI, 2023)
Lack of standardization of the retention phase has led to many studies of stability of movements and characteristic of retainers, disregarding the enamel repercussions of fixed retention on this phase. ...
Effect of temperature on the orthodontic clinical applications of NiTi closed-coil springs
(Medicina Oral S.L., 2013-07-01)
NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the ...
New bactericide orthodonthic archwire: NiTi with silver nanoparticles
(MDPI, 2020)
A potential new bactericide treatment for NiTi orthodontic archwires based in the electrodeposition of silver nanoparticles on the surface was studied. Twenty-five archwires were treated by electrodeposition, ...
Novel digital technique to analyze the accuracy and intraoperative complications of orthodontic self-tapping and self-drilling microscrews placement techniques: an in vitro study
(Elsevier, 2022)
Introduction: The objectives of this study were to analyze and compare the accuracy and intraoperative complications of orthodontic self-tapping and orthodontic self-drilling microscrew placement ...
Enamel evaluation after debonding of fixed retention and polishing treatment with three different methods
(MDPI, 2023)
Lack of standardization of the retention phase has led to many studies of stability of movements and characteristic of retainers, disregarding the enamel repercussions of fixed retention on this phase. ...
NiTi superelastic orthodontic archwires with polyamide coating
(Springer, 2013-10-24)
Twenty orthodontic archwires with 55.2 % Ni and 44.8 % Ti (% weight) were subjected to a dipping treatment to coat the NiTi surface by a polyamide polymer. It has been selected a Polyamide 11 due to its ...
In vitro study of shear bond strength in direct and indirect bonding with three types of adhesive systems
(MDPI, 2020)
This study aimed to compare the shear bond strength (SBS) and adhesive remaining index (ARI) using one conventional and two novel adhesive systems with clinical step reduction and direct and indirect ...
In vitro corrosion behavior of lingual orthodontic archwires
(Hindawi Publishing Corporation, 2011)
To investigate the in vitro electrochemical corrosive behavior of archwires used in lingual orthodontics and the effects on the phase transition temperatures. Materials and Methods. Six different types ...
Comparison of changes in the dental transverse and sagittal planes between patients treated with self-ligating and with conventional brackets
(Scientific Electronic Library Online, 2020)
Introduction: Several advantages have been established regarding the efficiency of self-ligating brackets (SL). In spite of some controversy surrounding this question in the literature, clinical results ...
Novel digital technique to analyze the accuracy and intraoperative complications of orthodontic self-tapping and self-drilling microscrews placement techniques: an in vitro study
(Elsevier, 2022)
Introduction: The objectives of this study were to analyze and compare the accuracy and intraoperative complications of orthodontic self-tapping and orthodontic self-drilling microscrew placement ...