Search
Now showing items 21-30 of 70
Los niños de La Cova de Valdavara (Becerreá, Lugo): análisis morfológico, patológico y del microdesgaste dental
(Sociedad de Ciencias Aranzadi, 2019)
Este artículo presenta un análisis holístico de los restos dentales pertenecientes a tres individuos infantiles del yacimiento de la Edad del Bronce de la Cueva de Valdavara (Becerréa, Lugo), mediante ...
Antibacterial properties of hLf1-11 peptide onto titanium surfaces: a comparison study between silanization and surface initiated polymerization
(ACS Publications, 2015)
Dental implant failure can be associated with infections that develop into peri-implantitis. In order to reduce biofilm formation, several strategies focusing on the use of antimicrobial peptides (AMPs) ...
Effect of temperature on the orthodontic clinical applications of NiTi closed-coil springs
(Medicina Oral S.L., 2013-07-01)
NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the ...
Prótesis removible en el paciente geriátrico
(Ediciones Avances, 2015)
En nuestro entorno sociodemográfico, según las condiciones económicas actuales, cada vez más pacientes ancianos optan por rehabilitar su boca mediante prótesis removible, y aún siendo las prótesis ...
Antifouling coatings for dental implants: PEG-like coatings on titanium by plasma polymerization
(American Vacuum Society, 2015-06)
Titanium dental implants are commonly used for the replacement of lost teeth, but they present a considerable number of failures due to the infection on surrounding tissues. The aim of this paper is the ...
Accuracy of implant casts generated with conventional and digital impressions: an In vitro study
(MDPI, 2018)
Purpose: The aim of this study was to compare the accuracy of digital dental impressions with the accuracy of impressions obtained via conventional techniques. Methods: Two different master models were ...
NiTi superelastic orthodontic archwires with polyamide coating
(Springer, 2013-10-24)
Twenty orthodontic archwires with 55.2 % Ni and 44.8 % Ti (% weight) were subjected to a dipping treatment to coat the NiTi surface by a polyamide polymer. It has been selected a Polyamide 11 due to its ...
Chitosan-recombinamer layer-by-layer coatings for multifunctional implants
(MDPI, 2017)
The main clinical problems for dental implants are (1) formation of biofilm around the implant—a condition known as peri-implantitis and (2) inadequate bone formation around the implant—lack of ...
Effect of implant macro-design on primary stability: a prospective clinical study
(Medicina Oral, 2016)
Background: Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of ...
Interproximal papilla stability around CAD/CAM and stock abutments in anterior regions: a 2-year prospective multicenter cohort study
(Quintessence Publishing, 2017)
The aim of this study was to compare the interproximal papilla stability of restorations supported by computer-aided design/computer-assisted manufacture (CAD/CAM) abutments to those supported by ...