<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>Màster Universitari en Odontologia Restauradora Estètica - Oficial</title>
<link>https://hdl.handle.net/20.500.12328/41</link>
<description/>
<pubDate>Thu, 10 Sep 2026 22:18:46 GMT</pubDate>
<dc:date>2026-09-10T22:18:46Z</dc:date>
<item>
<title>CAD-CAM systems VS conventional design. Quality evaluation.</title>
<link>https://hdl.handle.net/20.500.12328/920</link>
<description>CAD-CAM systems VS conventional design. Quality evaluation.
OBJECTIVE : The aim of this study was to determine, by using a comparative&#13;
scale, the quality of an indirect inlay done by two types of methods. Conventional&#13;
hand-maid inlay (group control) and CAD-CAM inlay. MATERIAL AND&#13;
METHODS : three groups were used to design both types of restoration : Graduate&#13;
Students (GS) Master students (MS) and teachers (T). The Conventional hand-maid&#13;
inlay (CHM) was done with with FILTEK composite, and the CAD-CAM inlay (CC)&#13;
was done with Lava ultimate. Five criteria were analyzed in this study : surface lustre&#13;
(SL), esthetic anatomical form (AF), marginal adaptation (MA), occlusal form&#13;
contact point (OFCP), evaluator’s general view (GV). All these quality criteria were&#13;
compared between CHM and CC, but also between each deferents operators.&#13;
RESULTS : The results of the study show statistically significant difference between&#13;
the quality of CHM and CC (p-valor &lt; 0,05). The null hypothesis was rejected. For&#13;
all group mingled, the average score for the CC was 1,94 versus 2,22 for the CHM.&#13;
More specifically, GS group showed statistically significant difference when&#13;
designing the inlay regardless of the type of method used (CHM and CC) versus MS&#13;
and T. However no statistically significant difference was observed between MS and&#13;
T. Analyzing with more details for each group, the study reveled better results for CC&#13;
than CHM for GS and T groups, but better results for CHM than CC for MS group.&#13;
CONCLUSION : With the limit of the study, we can say that CC design showed&#13;
better results than CHM design. But if we analyze with more details, MS group had&#13;
better results with CHM than CC design. We can conclude that CC is a good&#13;
alternative to CHM, but depending on the operator.
</description>
<pubDate>Mon, 19 Dec 2016 00:00:00 GMT</pubDate>
<guid isPermaLink="false">https://hdl.handle.net/20.500.12328/920</guid>
<dc:date>2016-12-19T00:00:00Z</dc:date>
</item>
</channel>
</rss>
