Impact of magnifying loupes on the finish lines of fixed prosthesis preparations
Data de publicació
2024ISSN
2673-1592
Resum
Background: The use of magnification appears to offer advantages in dental preparation for fixed prosthetics and is widely employed in clinical practice, although it has not yet been thoroughly documented. Therefore, the primary objective is to determine the impact of magnification on the quality of finish lines during the performance of preparations for fixed prostheses. Methods: Sixty-four natural teeth were randomized into two groups: Group O (preparation without additional magnification) and Group L (preparation with Kitus® 2.5× magnifying glasses). The teeth were prepared for full crowns, and the finish lines were evaluated under the OPMI® PicoZeiss dental microscope at 10× magnification, based on the criteria of Continuity, Roughness, and Thickness. Results: There were no significant differences between the groups in any of the parameters evaluated. In Thickness, Group O had a median (IQR) of 600 µm (500; 800 µm) and Group L, 600 µm (400; 800 µm). Group L was Continuous in 64.8% of the cases, Slightly Continuous in 26.1% of the evaluations, and Not Continuous in 9.1% of the cases, thus having a slight advantage over Group O, whose values were 58.0%, 35.2%, and 6.8%, respectively. Group L was Polished in 71.0% of the cases and Rough in 29.0% of the evaluations, against 69.3% and 30.7% of Group O, respectively. These results were obtained using IBM SPSS ® software, version 29.0. Conclusions: The 2.5× magnification magnifiers demonstrated a slight positive impact on improving the quality of dental preparations for fixed prostheses. Nevertheless, since the results are not statistically significant, it is difficult to extrapolate them to the broader population.
Tipus de document
Article
Versió del document
Versió publicada
Llengua
Anglès
Matèries (CDU)
616.3 - Patologia de l'aparell digestiu. Odontologia
Paraules clau
Pàgines
12
Publicat per
MDPI
Col·lecció
6; 3
Publicat a
Prosthesis
Citació recomanada
Nóbrega, Catarina; Manso, Maria da Conceição; Herrero-Climent, Mariano [et al.]. Impact of magnifying loupes on the finish lines of fixed prosthesis preparations. Prosthesis, 2024, 6(3), 631-642. Disponible en: <https://www.mdpi.com/2673-1592/6/3/44>. Fecha de acceso: 28 feb. 2025. DOI: 10.3390/prosthesis6030044
Aquest element apareix en la col·lecció o col·leccions següent(s)
- Odontologia [342]
Drets
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Excepte que s'indiqui una altra cosa, la llicència de l'ítem es descriu com https://creativecommons.org/licenses/by/4.0/


