Mostrar el registro sencillo del ítem

dc.contributor.authorLeón, Javier
dc.contributor.authorCarrascosa, Alejandro
dc.contributor.authorRodríguez, Xavier
dc.contributor.authorRuiz-Magaz, Vanessa
dc.contributor.authorPascual, Andrés
dc.contributor.authorNart, José
dc.date.accessioned2024-01-22T14:04:13Z
dc.date.available2024-01-22T14:04:13Z
dc.date.issued2014
dc.identifier.citationLeón, Javier; Carrascosa, Alejandro; Rodríguez, Xavier [et al.]. Finite element analysis relative to the crestal position of a 3.0-mm-diameter implant. The International Journal of Periodontics & Restorative Dentistry, 2014, 34, p. 381-387. Disponible en: <https://www.quintpub.com/journals/prd/abstract.php?iss2_id=1230&article_id=14408&article=12&title=Finite%20Element%20Analysis%20Relative%20to%20the%20Crestal%20Position%20of%20a%203.0-mm-Diameter%20Implant#.U_3w9kuRNZg>. Fecha de acceso: 22 ene. 2024. DOI: 10.11607/prd.1960ca
dc.identifier.issn0198-7569ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/3927
dc.description.abstractIt has been shown that implant designs and different vertical positions have an influence on crestal bone. The purpose of this study was to use finite element (FE) analysis to biomechanically investigate the influence of the stress/strain distribution in a maxillary anterior 3.0-mm-diameter implant in relation to its apicocoronal level after oblique loading. Two different FE models, depending on implant position relative to bone crest, were applied. It can be concluded that placing the implant-abutment interface supracrestally provides decreased levels of stress and strain in the surrounding bone. However, placing the implant 0.5 mm supracrestally is also acceptable according to this analysis.ca
dc.format.extent6ca
dc.language.isoengca
dc.publisherQuintessence Publishingca
dc.relation.ispartofThe International Journal of Periodontics & Restorative Dentistryca
dc.relation.ispartofseries34;3
dc.subject.otherImplants dentalsca
dc.subject.otherImplantes dentalesca
dc.subject.otherDental implantsca
dc.titleFinite element analysis relative to the crestal position of a 3.0-mm-diameter implantca
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc616.3ca
dc.identifier.doihttps://dx.doi.org/10.11607/prd.1960ca


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Compartir en TwitterCompartir en LinkedinCompartir en FacebookCompartir en TelegramCompartir en WhatsappImprimir