Three-dimensional evaluation of the accuracy of zygomatic implant placement through an in-house fully guided approach
Autor/a
Fecha de publicación
2023ISSN
0882-2786
Resumen
Purpose: To validate guided surgery for zygomatic implants (ZIs) by analyzing the final position of the implants relative to the preoperatively planned position. Material and Methods: Five patients with fully edentulous atrophic maxillae treated with four ZIs through a fully guided implant surgical approach were evaluated. The preoperative phase included digital planning, through which the surgical guide was designed and created. Analysis of the guided surgery accuracy was carried out by superimposing the digital planning over the final position of the implants using preoperative and postoperative CBCT. The radiologic evaluation included implant angular deviation, entrance deviation, exit deviation, platform deviation, and apex apicocoronal and mesiodistal deviation. Results: All five patients (two men and three women; mean age: 61.8 ± 3 years) were each treated with four ZIs using a fully guided approach with an extrasinusal path, obtaining ideal emergence of the implants. Superimposition comparison found a mean axial angular implant deviation of 0.79 ± 0.41 degrees and a mean implant entrance deviation of 0.95 ± 0.26 degrees. The platform deviation was 0.62 ± 0.19 mm buccopalatally and 0.76 ± 0.14 mm mesiodistally, while the apical deviation was 0.42 ± 0.13 mm buccopalatally and 1.06 ± 0.37 mm mesiodistally. Conclusions: Guided surgery in zygomatic implants appears to be sufficiently accurate to make it a safe and predictable technique.
Tipo de documento
Artículo
Versión del documento
Versión publicada
Lengua
Inglés
Materias (CDU)
616.3 - Patología del aparato digestivo. Odontología
Palabras clave
Páginas
9
Publicado por
Quintessence Publishing
Colección
38; 4
Publicado en
The International Journal of Oral & Maxillofacial Implants
Citación recomendada
Hernandez Alfaro, Federico; Bertos Quílez, Jorge; Valls-Ontañón, Adaia [et al.]. Three-dimensional evaluation of the accuracy of zygomatic implant placement through an in-house fully guided approach. The International Journal of Oral & Maxillofacial Implants, 2023, 38(4), p. 747-756. Disponible en: <https://www.quintessence-publishing.com/usa/en/article/4331339/the-international-journal-of-oral-maxillofacial-implants/2023/04/three-dimensional-evaluation-of-the-accuracy-of-zygomatic-implant-placement-through-an-in-house-fully-guided-approach>. Fecha de acceso: 21 nov. 2024. DOI: 10.11607/jomi.10045
Este ítem aparece en la(s) siguiente(s) colección(ones)
- Odontologia [345]
Derechos
© The International Journal of Oral & Maxillofacial Implants