Show simple item record

dc.contributor.authorPellegrino, Antonio
dc.contributor.authorBurd, Harvey John
dc.contributor.authorPinilla Cortés, Laura
dc.contributor.authorD'Antin, Justin Christopher
dc.contributor.authorPetrinic, Nik
dc.contributor.authorBarraquer, Rafael I.
dc.contributor.authorMichael, Ralph
dc.date.accessioned2024-02-05T14:57:25Z
dc.date.available2024-02-05T14:57:25Z
dc.date.issued2018
dc.identifier.citationPellegrino, Antonio; Burd, Harvey John; Pinilla Cortés, Laura [et al.]. Anterior lens capsule strains during simulated accommodation in porcine eyes. Experimental Eye Research, 2018, 168, p. 19-27. Disponible en: <https://www.sciencedirect.com/science/article/abs/pii/S0014483517306048?via%3Dihub>. Fecha de acceso: 5 feb. 2024. DOI: 10.1016/j.exer.2017.12.008ca
dc.identifier.issn0014-4835ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/4011
dc.description.abstractExperimental protocols have been developed to measure the spatial variation of the mechanical strains induced in the lens capsule during ex vivo lens stretching. The paper describes the application of these protocols to porcine lenses. The deformations and mechanical strains developed in the anterior capsule during each experiment were determined using full field digital image correlation techniques, by means of a speckle pattern applied to the lens surface. Several speckling techniques and illumination methods were assessed before a suitable combination was found. Additional data on the cross section shape of the anterior lens surface were obtained by Scheimpflug photography, to provide a means of correcting for lens curvature effects in the determination of the strains developed in the plane of the capsule. The capsule strains in porcine lenses exhibit non-linear behaviour, and hysteresis during loading and unloading. Peripheral regions experience higher magnitude strains than regions near the lens pole. The paper demonstrates the successful application of a procedure to make direct measurements of capsule strains simultaneously with ex vivo radial lens stretching. This experimental technique is applicable to future investigations on the mechanical characteristics of human lenses.ca
dc.format.extent8ca
dc.language.isoengca
dc.publisherElsevierca
dc.relation.ispartofExperimental Eye Researchca
dc.relation.ispartofseries168
dc.rights© 2017 Elsevier Ltd. All rights reserved.ca
dc.subject.otherOftalmologiaca
dc.subject.otherOftalmologíaca
dc.subject.otherOphtalmologyca
dc.titleAnterior lens capsule strains during simulated accommodation in porcine eyesca
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc617ca
dc.identifier.doihttps://dx.doi.org/10.1016/j.exer.2017.12.008ca


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Share on TwitterShare on LinkedinShare on FacebookShare on TelegramShare on WhatsappPrint