Show simple item record

dc.contributor.authorLops, Diego
dc.contributor.authorParpaiola, Andrea
dc.contributor.authorPaniz, Gianluca
dc.contributor.authorSbricoli, Luca
dc.contributor.authorRuiz Magaz, Vanessa
dc.contributor.authorCenzi Venezze, Alvise
dc.contributor.authorBressan, Eriberto
dc.contributor.authorStellini, Edoardo
dc.date.accessioned2024-01-22T15:23:42Z
dc.date.available2024-01-22T15:23:42Z
dc.date.issued2017
dc.identifier.citationLops, Diego; Parpaiola, Andrea; Paniz, Gianluca [et al.]. Interproximal papilla stability around CAD/CAM and stock abutments in anterior regions: a 2-year prospective multicenter cohort study. The International Journal of Periodontics & Restorative Dentistry, 2017, 37(5), p. 657-665. Disponible en: <https://quintpub.com/journals/prd/abstract.php?iss2_id=1477&article_id=17662>. Fecha de acceso: 22 ene. 2024. DOI: 10.11607/prd.3184ca
dc.identifier.issn0198-7569ca
dc.identifier.urihttp://hdl.handle.net/20.500.12328/3933
dc.description.abstractThe aim of this study was to compare the interproximal papilla stability of restorations supported by computer-aided design/computer-assisted manufacture (CAD/CAM) abutments to those supported by prefabricated stock abutments in anterior areas over a 2-year follow-up. Abutments were selected depending on implant inclination and thickness of buccal peri-implant soft tissues from the following: zirconia stock, titanium stock, zirconia CAD/CAM and titanium CAD/CAM. Differences between the height of the papilla tip were measured (REC). Results: REC values of titanium and zirconia CAD/CAM abutments were significantly lower than those of titanium and zirconia stock. The use of titanium and zirconia CAD/CAM abutments is related to better interproximal papillae stability.ca
dc.format.extent8ca
dc.language.isoengca
dc.publisherQuintessence Publishingca
dc.relation.ispartofThe International Journal of Periodontics & Restorative Dentistryca
dc.relation.ispartofseries37;5
dc.subject.otherOdontologiaca
dc.subject.otherOdontologíaca
dc.subject.otherDentistryca
dc.titleInterproximal papilla stability around CAD/CAM and stock abutments in anterior regions: a 2-year prospective multicenter cohort studyca
dc.typeinfo:eu-repo/semantics/articleca
dc.description.versioninfo:eu-repo/semantics/publishedVersionca
dc.rights.accessLevelinfo:eu-repo/semantics/openAccess
dc.embargo.termscapca
dc.subject.udc616.3ca
dc.identifier.doihttps://dx.doi.org/10.11607/prd.3184ca


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Share on TwitterShare on LinkedinShare on FacebookShare on TelegramShare on WhatsappPrint