Abstract
This study shows the potential risk of microfiltration between two different types of implant-abutment connections screwed at 45 Ncm: external and internal. For the first time the use of a mechanical artificial mouth is used with the values (compression and torsion loads with a frequency of 2 Hz) of the human chewing. The mechanical tests were performed with an artificial saliva at 37 degrees C. The microgap in the connection was measured by an Image Analysis software incorporated in a high resolution scanning electron microscopy. Implant connections were filled with methylene blue by using self-adjustable precision pipettes and the quantity of leakage was determined by high sensitivity spectometry. We showed that the internal connection has lower microgaps compared to the external ones and these microgaps increased with the number of mechanical cycles. The leakage of methylene blue was higher when the external connection was performed. Microgaps and the influence of the mechanical loads are very important for the long-term behavior avoiding the bacteria colonization in the dental implants. These aspects should be known by the implantologists.
Document Type
Article
Document version
Accepted version
Language
English
Subject (CDU)
616.3 - Pathology of the digestive system. Complaints of the alimentary canal
Keywords
Implants dentals
Bacteris
Titani
Inflamació
Implantes dentales
Bacterias
Titanio
Inflamación
Dental implants
Bacteria
Titanium
Inflammation
Pages
7
Publisher
Springer
Collection
26; 7
Is part of
Journal of Materials Science: Materials in Medicine
Citation
Martin Gili, David; Molmeneu Trias, Meritxell; Fernández Yagüe, Marc Antoni [et al.]. Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth. Journal of Materials Science. Materials in Medicine, 2015, 26(7), [p. 1-7]. Disponible en: <https://link.springer.com/article/10.1007/s10856-015-5544-x>. Fecha de acceso: 5 may 2020. DOI: 10.1007/s10856-015-5544-x
Grant agreement number
info:eu-repo/grantAgreement/MINECO/6PN/MAT2012-30706
This item appears in the following Collection(s)
- Ciències de la Salut [740]
Rights
© 2020 Springer Nature Switzerland AG.