Osteo-odonto-, tibial bone and Boston keratoprosthesis in clinically comparable cases of chemical injury and autoimmune disease
(Elsevier, 2019)
Purpose: To compare anatomical and functional results between three types of keratoprosthesis (KPro) in chemical injury and autoimmune disease. Methods: 70 clinically comparable cases were included as ...
Comparison of long-term results between osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis
(Elsevier, 2018)
Purpose: To compare the anatomical and the functional results between osteo-odonto-keratoprosthesis (OOKP) and keratoprosthesis using tibial bone autograft (Tibial bone KPro). Methods: We reviewed the ...
Incidence and reasons for intrastromal corneal ring segment explantation
(Elsevier, 2021)
Purpose: To determine the main causes of intrastromal corneal ring segment (ICRS) explantation and define the incidence rate. Design: Multicenter, observational consecutive case series. Methods: Consecutive ...
Deformations and ruptures in human lenses with cortical cataract subjected to ex vivo simulated accommodation
(Association for Research in Vision and Ophthalmology, 2021)
Purpose: Human cortical opacities are most commonly accompanied by changes in lens fiber structure in the equatorial region at the lens nucleus–cortex interface. Cortex and nucleus have different elastic ...
Long-term follow-up of partial bleb excision in late-onset bleb-related complications by a single surgeon using conjunctival advancement
(Wolters Kluwer, 2019)
Purpose: The purpose of this study was to describe the long-term results of partial bleb excision in late-onset bleb-related complications by a single experienced surgeon using the same surgical technique. ...
Anterior lens capsule strains during simulated accommodation in porcine eyes
(Elsevier, 2018)
Experimental protocols have been developed to measure the spatial variation of the mechanical strains induced in the lens capsule during ex vivo lens stretching. The paper describes the application of ...
Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
(Springer Nature, 2022)
Background: The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) ...
Localized refractive changes induced by symmetric and progressive asymmetric intracorneal ring segments assessed with a 3D finite-element model
(MDPI, 2023)
To build a representative 3D finite element model (FEM) for intracorneal ring segment (ICRS) implantation and to investigate localized optical changes induced by different ICRS geometries, a hyperelastic ...
Refractive changes of a new asymmetric intracorneal ring segment with variable thickness and base width: a 2D finite-element model
(Public Library of Science, 2021)
Purpose: To evaluate the local geometric effects of a unilateral intrastromal ring segment with a combined variation of ring thickness and base width in a finite element simulation, and to compare it ...