Show simple item record

dc.contributorNart Molina, José
dc.contributorSantos Alemany, Antonio
dc.contributorUniversitat Internacional de Catalunya. Departament d'Odontologia
dc.contributor.authorSanz Moliner, Javier Daniel
dc.date.issued2012-08-02T10:53:11Z
dc.date.issued2014-08-03T05:45:05Z
dc.date.issued2012-07-06
dc.identifierhttp://hdl.handle.net/10803/83931
dc.identifierB. 24447-2012
dc.description.abstractThe purpose of this study was to clinically compare the use of a 810 nm diode laser (DL) following modified Widman flap (test sites) to that of modified Widman flap (MWF) alone (control sites). Thirteen patients with periodontal pockets in two different quadrants with at least one tooth exhibiting a pocket depth of >7 millimeters and attachment levels of >7mm were selected. One side was randomly selected to receive MWF and the other to receive a diode laser following MWF. The DL was used to de-epithelialize the inner part of the periodontal flap and photo-biostimulate the surgical area. Probing depth (PD), clinical attachment levels (CAL), plaque index (PI), and gingival index (GI) were evaluated at baseline, 6 weeks and 5 months. Pain scale assessment (PS), pain medication consumption (PM), tissue edema (TE), and tissue color (TC) were evaluated one week following surgery. Treatment differences were analyzed using McNemar’s test, paired t-tests or a Wilcoxon Signed Rank Test. No statistical differences of CAL gain, PD, GI and PI reduction between laser sites and control sites were seen. Statistically significant differences were seen for TE (p=0.041), PM (p<0.001) and PS (p<0.001) favoring test sites. TC did not show a statistically significant difference (p=0.9766). Patients rated the first surgical treatment performed as more painful than the second (p<0.002). The use of a 810 nm diode laser following modified Widman flap provided additional benefits in terms of less edema and post operative pain.
dc.format129 p.
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languageeng
dc.publisherUniversitat Internacional de Catalunya
dc.rightsL'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.sourceTDX (Tesis Doctorals en Xarxa)
dc.subjectClinical trial
dc.subjectLaser
dc.subjectPeriodontal surgery
dc.subjectWound healing
dc.subject616.3
dc.titleA 810 nm Diode Laser following Modified Widman Flap Surgery
dc.typeinfo:eu-repo/semantics/doctoralThesis
dc.typeinfo:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Share on TwitterShare on LinkedinShare on FacebookShare on TelegramShare on WhatsappPrint